Fire Dampers - DFD-100
Model DFD-110 is for use in walls, floors, and partitions with a fire-resistance rating less than three hours. This model has a 2³/₁₆ inch (56 mm) frame. Dynamic-rated-fire dampers are in HVAC systems that remain operational in the event of a fire.
Pressure: Up to 4 in. wg (1 kPa)
Velocity: Up to 4000 fpm (20.3 m/s)
Temperature: Up to 286°F (141°C)
1.00
Rs.
Fire Dampers - DFD-150
Model DFD-150 is for use in walls, floors, and partitions with fire-resistance ratings less than three hours. This model has a 3¹¹/₁₆ inch (94 mm) frame. Dynamic-rated-fire dampers are in HVAC systems that remain operational in the event of a fire.
Pressure: Up to 4 in. wg (1 kPa)
Velocity: Up to 4000 fpm (20.3 m/s)
Temperature: Up to 286°F (141°C)
1.00
Rs.
Fire Dampers - DFD-150X SERIES
The DFD-150X series is for use in walls, floors, and partitions with fire-resistance ratings less than three hours. This model has an integral sleeve. Dynamic-rated-fire dampers are in HVAC systems that remain operational in the event of a fire.
Pressure: Up to 4 in. wg (1 kPa)
Velocity: Up to 4000 fpm (20.3 m/s)
Temperature: Up to 286°F (141°C)
DFD-150x12 has integral 12-inch sleeve (305mm)
DFD-150x16 has integral 16-inch sleeve (406 mm)
1.00
Rs.
Fire Dampers - DFD-210
The DFD-210 is a multi-blade 3V dynamic-rated-fire damper used in walls, floors, and partitions with fire-resistance ratings less than three hours. Dynamic-rated-fire dampers are in HVAC systems that remain operational in the event of a fire.
Pressure: Up to 10 in. wg (2.5 kPa)
Velocity: Up to 4000 fpm (20.3 m/s)
Temperatures: Up to 350°F (177°C)
1.00
Rs.
Fire Dampers - DFD-310
Model DFD-310 is for use in walls, floors, and partitions with fire-resistance ratings of three hours or more. This model has a 2³/₁₆ inch (56 mm)frame. Dynamic-rated-fire dampers are used with HVAC systems that remain operational during a fire emergency.
Pressure: Up to 4 in. wg (1 kPa)
Velocity: Up to 4000 fpm (20.3 m/s)
Temperature: Up to 286°F (141°C)
1.00
Rs.
Fire Dampers - DFD-350
Model DFD-350 is for use in walls, floors, and partitions with fire-resistance ratings of three hours or more. This model has a 3¹¹/₁₆ inch (94 mm) frame. Dynamic-rated-fire dampers are used with HVAC systems that remain operational during a fire emergency.
Pressure: Up to 4 in. wg (1 KPa)
Velocity: Up to 4000 fpm (20.3 m/s)
Temperature: Up to 286°F (141°C)
1.00
Rs.
Fire Dampers - DFDAF-310
Model DFDAF-310 is a multi-blade airfoil dynamic-rated-fire damper used in walls, floors, and partitions with fire-resistance ratings less than three hours. Dynamic-rated-fire dampers are in HVAC systems that remain operational in the event of a fire.
Pressure: Up to 8 in. wg (2 kPa)
Velocity: Up to 4000 fpm (20.3 m/s)
Temperatures: Up to 350°F (177°C)
1.00
Rs.
Fire Dampers - DFDAF-330
Model DFDAF-330 is a multi-blade dynamic-rated-fire damper with airfoil style blades for use in walls, floors, and partitions with fire-resistance ratings of three hours or more. Dynamic-rated-fire dampers are used with a HVAC systems that remain operational during a fire emergency.
Pressure: Up to 8 in. wg (2 kPa)
Velocity: Up to 4000 fpm (20.3 m/s)
Temperatures: Up to 350°F (177°C)
1.00
Rs.
Fire Dampers - DFDR-510
Model DFDR-510 is a round fire damper for use in walls, floors, and partitions with fire-resistance ratings less than three hours. Dynamic-rated-fire dampers are in HVAC systems that remain operational in the event of a fire.
Pressure: Up to 4 in. wg (1 kPa)
Velocity: Up to 2000 fpm (10.2 m/s)
Temperature: Up to 286°F (141°C)
1.00
Rs.
Fire Dampers - FD-110
Model FD-110 is for use in walls, floors, and partitions with fire-resistance ratings less than three hours. This model has a 2³/₁₆ inch (56 mm) frame. Static-rated-fire dampers used in HVAC systems automatically shut down in the event of a fire.
1.00
Rs.
Fire Dampers - FD-150
The FD-150 is for use in walls, floors, and partitions with fire-resistance ratings less than three hours. This model has a 3¹¹/₁₆ inch (94 mm) frame. Static-rated-fire dampers used in HVAC systems automatically shut down in the event of a fire emergency.
1.00
Rs.
Fire Dampers - FD-150X Series
The FD-150X series is for use in walls, floors, and partitions with fire-resistance ratings less than three hours. This model has an integral sleeve. Static-rated-fire dampers used in HVAC systems that automatically shut down in the event of a fire emergency.
Temperature: Up to 212°F (100°C)
FD-150x12 has integral 12-inch sleeve (305 mm)
FD-150x16 has integral 16-inch sleeve (406 mm)
1.00
Rs.
Fire Dampers - FD-310
Model FD-310 is for use in walls, floors, and partitions with fire resistance ratings of three hours or more. This model has a 2³/₁₆ inch (56 mm) frame. Static rated fire dampers used in HVAC systems automatically shut down in the event of a fire emergency.
Temperature: Up to 212°F (100°C)
1.00
Rs.
Fire Dampers - FD-350
Model FD-350 is for use in walls, floors, and partitions with fire-resistance ratings of three hours or more. This model is UL 555 classified with a 3¹¹/₁₆-in ch (94 mm) frame. Static rated fire dampers used in HVAC systems automatically shut down in the event of a fire emergency.
Temperature: Up to 212°F (100°C)
1.00
Rs.
Fire Dampers - KFD-150
The KFD-150 is a static rated fire damper used in kitchen ventilation systems. This model has a fire-resistance rating of less than three hours. Static rated fire dampers are used in systems that automatically shut down in the event of a fire emergency.
1.00
Rs.
Fire Dampers - KFD-350
The KFD-350 is used in kitchen ventilation system with a fire resistance rating of 3 hours or more. Static rated fire dampers used in HVAC systems automatically shut down in the event of a fire emergency.
1.00
Rs.
Fire Dampers - ODFD-150
Model ODFD-150 is an out-of-wall fire damper for use in walls or partitions with less than three hour fire-resistance rating. Dynamic-rated-fire dampers are in HVAC systems that remain operational in the event of a fire.
Pressure: Up to 4 in. wg (1 kPa)
Velocity: Up to 4000 fpm (20.3 m/s)
Temperature: Up to 212°F (100°C)
1.00
Rs.
Fire Dampers - OFD-150
The OFD-150 is an out-of-wall fire damper for use in HVAC systems that automatically shut down in the event of a fire. This model is rated for use in walls or partitions with less than a three hour fire-resistance rating.
Temperature: Up to 212°F (100°C)
1.00
Rs.
Fire Dampers - SEDFD-210
Model SEDFD-210 is a 3V multi-blade-fire damper for use in walls, floors, and partitions with fire-resistance ratings less than three hours. Dynamic-rated-fire dampers are in HVAC systems that remain operational in the event of a fire.
316 stainless steel construction
Pressure: Up to 10 in. wg (2.5 kPa)
Velocity: Up to 4000 fpm (20.3 m/s)
Temperatures: Up to 350°F (177°C)
1.00
Rs.
Fire Dampers - SSDFD-150
Model SSDFD-150 is for use in walls and partitions with fire-resistance ratings less than three hours. This model has a 3¹¹/₁₆ inch (94 mm) frame. Dynamic-rated-fire dampers are in HVAC systems that remain operational in the event of a fire.
1.00